Strany 1 - SysKonnect

SysKonnectSK-9Exx/9SxxUser ManualSK-9Exx and SK-9Sxx Gigabit Ethernet Server Adapters

Strany 2

10 Table of Figures

Strany 3 - User Manual

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersSafety PrecautionsTo protect yourself from injuries and avoid damage of the device, always obs

Strany 4

12 Safety PrecautionsFor 1000Base-LX/SX adapters observe the following:The laser components on the network adapter are Class 1 laser components. Clas

Strany 5 - Conventions

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server Adapters1 Installation of the Network AdapterThe installation procedure in Hot-Plug systems may differ

Strany 6 - 6 Conventions

14 1 Installation of the Network AdapterFigure 1. Insertion of the adapter into the computer

Strany 7 - Table of Contents

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server Adapters2 Connection of the Network AdapterThis chapter describes the physical connection of the netwo

Strany 8 - 8 Table of Contents

16 2 Connection of the Network Adapter Figure 2. Connection of fiber-optics cables/plugs7. Turn on the computer and the switch.If no protocol drive

Strany 9 - Table of Figures

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server Adapters3 Installation of the Driver SoftwareThe network drivers are located in the appropriate produc

Strany 10 - 10 Table of Figures

18 3 Installation of the Driver SoftwareWindowsSysKonnect offers drivers for Windows Server 2003, Windows XP, Windows 2000, Windows Me,Windows 98 SE,

Strany 11 - Safety Precautions

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersWindows 19Windows 98 Second EditionSysKonnect offers an NDIS 5.0 32-bit Miniport driver for th

Strany 13

20 3 Installation of the Driver Software7. Type the path to the driver, e.g. e:\SK-9Exx\Windows\WinME, where “e” is the designationof the CD-ROM drive

Strany 14

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersLinux 21Windows XP and Windows Server 2003SysKonnect offers an NDIS 5.1 32-bit Miniport driver

Strany 15 - Connection to the Network

22 3 Installation of the Driver SoftwareUsing the option EXPERT INSTALLATION, the driver is also compiled automatically and the resultingdriver module

Strany 16

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server Adapters4 Hardware FeaturesThe SysKonnect SK-9Exx/SK-9Sxx Gigabit Ethernet Adapter Family defines a se

Strany 17

24 4 Hardware FeaturesAdapter CharacteristicsThe following table lists the characteristics of the SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Serv-er Ada

Strany 18 - Windows NT 4.0

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersLED Displays 25LED DisplaysOnce the driver has been installed, the adapter is operational. The

Strany 19 - Windows Millennium Edition

26 4 Hardware FeaturesAdapter Variant 2Figure 5. Location of the LEDs (adapter variant 2)The LEDs of the copper adapters variant 2 have the following

Strany 20 - Windows 2000

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server Adapters5 Software FeaturesOperating System SupportThe drivers for the SysKonnect SK-9Exx/9Sxx Gigabit

Strany 21 - Linux 21

28 5 Software FeaturesPXE / RPL SupportThe SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server Adapter Family supports both the standardPXE 2.1 (Pre-Boot

Strany 22

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersUser Diagnostics (DOS) 29The following conditions have to be met in order for Hot-Plug to work

Strany 23 - 4 Hardware Features

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersSysKonnect SK-9Exx and SK-9SxxGigabit Ethernet Server AdaptersUser Manual(v1.00 / 4 January, 2

Strany 24 - Adapter Characteristics

30 5 Software FeaturesFor several operating systems, SysKonnect offers drivers that support VLAN tagging and thus canbe applied for VLAN servers and t

Strany 25 - LED Displays

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server Adapters6 Testing the Network AdapterDiagnostics ProgramThe network adapter can be tested with the sup

Strany 26 - Adapter Variant 2

32 6 Testing the Network AdapterTo test the adapter, proceed as follows:1. Switch off the computer. 2. If the computer is still connected to the data

Strany 27 - 5 Software Features

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersDiagnostics Program 33Loopback Repeater TestTo perform the loopback repeater test, you will ha

Strany 28 - Reliability

34 6 Testing the Network AdapterFailure of a TestFigure 8. Typical error message from the diagnostics programFor a test to be completed successfully,

Strany 29 - Virtual LAN (VLAN) support

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersAdditional Functions of the Diagnostics Program 3510. If necessary, remove the wrap plug from

Strany 30 - 30 5 Software Features

36 6 Testing the Network AdapterReading Sensor DataTo read sensor data, proceed as follows:1. Start the main program (see page 35).2. Select SHOW SENS

Strany 31 - 6 Testing the Network Adapter

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersAdditional Functions of the Diagnostics Program 37Figure 10. Display of configuration dataRead

Strany 32 - XIT in the main menu

38 6 Testing the Network Adapter3. Select the desired optionor return to the main menu by selecting EXIT (default option).Sample Usage of VPD / Asset

Strany 33 - Loopback Repeater Test

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersAdditional Functions of the Diagnostics Program 39Figure 13. Screen showing updated asset tagF

Strany 34 - Failure of a Test

4 Copyright © SysKonnect GmbH, 2004. All rights reserved.This manual refers to the adapters of the SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Adapter F

Strany 35 - Starting the Main Program

40 6 Testing the Network Adapter

Strany 36 - Reading Configuration Data

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server Adapters7 TroubleshootingIf the problem persists, you can analyze the status of the network adapter wi

Strany 37

42 7 Troubleshooting

Strany 38

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server Adapters8 Important InformationTechnical SupportIf you encounter any problems, read the relevant chapt

Strany 39

44 8 Important Information2. Complete the form.3. Return the form to us.We will send you a unique reference number and inform you if the product is st

Strany 40

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersTechnical Specifications 45Technical SpecificationsNetwork interface standardIEEE 802.3 and IE

Strany 41 - 7 Troubleshooting

46 8 Important InformationDimensions (max.) (without bracket)SK-9E21: 118.4 mm x 60.3 mm SK-9S21: 167.64 mm x 57.3 mm SK-9E22: 11

Strany 42 - 42 7 Troubleshooting

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersHow to Identify your Network Adapter Type 47How to Identify your Network Adapter TypeIf you ar

Strany 43 - 8 Important Information

48 8 Important InformationAdapter Variant 2Model SK-9E21SK-9S21SK-9E22SK-9S22SK-9E81SK-9S81SK-9E82SK-9S82SK-9E91SK-9S91SK-9E92SK-9S92BracketInterface/

Strany 44 - 44 8 Important Information

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server Adapters Appendix A. License and Warranty InformationThe Americas, Asia, Australia, New Zealand, Pacif

Strany 45 - Technical Specifications

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersConventionsThe following conventions apply to this manual.Warnings and NotesFont Styles applie

Strany 46 - 46 8 Important Information

50 Appendix A. License and Warranty InformationCustomer RemediesSysKonnect's entire liability and your exclusive remedy shall be, at SysKonnect&a

Strany 47 - Adapter Variant 1

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersDeutschland, Schweiz, Österreich, Liechtenstein 51HardwareThe risk passes to you, the end user

Strany 48

52 Appendix A. License and Warranty Informationanderen Speichervorrichtung eines Computers, der kein Netzserver ist, installiert wird und eine einzige

Strany 50

Visit us:www.syskonnect.comSysKonnect GmbHSiemensstrasse 23D-76275 EttlingenSupport: +49 7243 502 330E-mail: [email protected]

Strany 51

6 ConventionsCourier: Courier is used for the following elements:• Terminal input to be entered by the user• Terminal output issued by the systemExam

Strany 52 - Hardware

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersTable of ContentsConventions 5Warnings and Notes 5Font Styles applied 5Safety Precautions

Strany 53

8 Table of ContentsAdditional Functions of the Diagnostics Program 35Checking Other Displays and Data 35Starting the Main Program 35Reading Sensor

Strany 54 - Visit us:

SysKonnect SK-9Exx/9Sxx Gigabit Ethernet Server AdaptersTable of FiguresFigure 1: Insertion of the adapter into the computer 14Figure 2: Connection o